Delta, Adaptive Delta & Delta Sigma Modulation Demodulation Trainer (VPL-CT-ADM)

SALIENT FEATURES

  • Both Transmitter & Receiver on same board.
  • Clock generation from crystal.
  • 4 switch selectable sampling rates.
  • On – Board Generators at 4 different frequencies (Synchronized).
  • Separate Adjustable DC Level.
  • Selectable integrator gain setting (by switch or control circuit).
  • On – Board 4th order butter worth L.P. Filter.
  • Unipolar to Bipolar conversion On – Board.

SKU: VPL-CT-ADM Category:

TECHNICAL SPECIFICATIONS

  •  Crystal Frequency : 4.096 MHz.
  •  Sampling Frequencies : 32 KHz, 64KHz, 128KHz, 256KHz, (switch selectable).
  •  On – Board Generator : Synchronized & Adjustable Amplitude Sine wave Generator at 250Hz, 500 Hz, 1KHz, 2KHz, Separate variable D.C. Level.
  •  Integrator : 4 Integrator gain setting norm, X 2 X 4 X 8.
  •  LP Filters : 4th order Butterworth (3.4 KHz cut off frequency).
  •  Test Points : More than 55.
  •  Interconnections : 2/4 mm socket.
  •  Cabinet : Enclosed in ABS plastic cabinet with detachable cover.
  •  Power : 220V AC ±10%, 50/60Hz mains operated.
  •  Accessories : Set of Patch Cords, User’s manual.

 

LIST OF EXPERIMENTS

  •  Delta Modulation & Demodulation.
  •  Effect of slope overload and increased integrator gain in Delta Modulation Adaptive Delta Modulation & Demodulation.
  •  Delta Sigma Modulation & Demodulation.
  •  Amplitude overload in Delta Sigma Modulation.

 

OPTIONAL ACCESSORIES
♦ Multimedia interactive computer based training manual