Digital Storage Oscilloscopes (50MHz / 100MHz) (VPL-2052 / 2102)
CHARACTERISITCS
- Bandwidth : 50MHz / 100MHz
- Real-time Sampling Rate : 500MS/s / 1GS/s
Sampling
- Equivalent sampling : 25 GS/s
- Sampling : Sampling, peak detect, average
- Average value : When all channels have made N samplings simultaneously, N is selectable from 2, 4, 8, 16, 32, 64, 128 to 256
InputS
- Input coupling : DC, AC, GND
- Input impedance : 1MW±2% in parallel with 20±3pF
- Probe attenuation factor : 1X, 10X, 100X, 1000X
- Maximum input voltage : 400V (DC + AC Peak, 1MW input impedance)
- Time delay between : 150ps
- channels (Typical)
Horizontal
- Waveform interpolation : Sin (x) / x
- Saving depth : 25K for single channel; 12.5K for dual channels
- Scanning range (s/div) : 5ns/div-50s/div (VPL-2052, at 1-2-5 increment). 2ns/div-50s/div (VPL- 2102, at 1-2-5 increment);
- Accuracy of sampling rate : ±50ppm
- and delay time (any time interval =1ms)
- Time interval (DT) : Single : ± (1 sampling time
- Measurement accuracy interval + 50ppm x reading
- (full bandwidth) + 0.6ns); >16 average values : ± (1 sampling time interval + 100ppm x reading + 0.4ns)
FEATURES
- 500MSa/s / 1GSa/s Sampling Rate
- 2 Channels
- 7 in LCD Color Display
APPLICATIONS
- Industrial Power Design, Troubleshooting, Installation, and Maintenance.
- Electronics Design, Troubleshooting, Installation, and Maintenance
- Circuit Design & Debug
- Educational Lab & Training Institutions
- Repair & Service
- Production Test & Quality Inspection
Vertical
- A/D converter : 8-bit resolution
- Deflection factor range : 1 mV/div ~ 20V/div (at input (VOLTS/DIV) BNC)
- Position range : ± 10 div
- Analog bandwidth : 50MHz (VPL-2052) 100MHz (VPL-2102)
- Single bandwidth : 50MHz (VPL-2052) 100MHz (VPL-2102)
- Selectable analog : 20MHz
- bandwidth limit (Typical)
- Low frequency response : £ 10 Hz at BNC
- (AC coupling, -3dB)
- Rise time : £3.5ns, £7ns at 100MHz and 50MHz bandwidths respectively
- DC gain accuracy:
*When vertical sensitivity is 1mV/div~2mV/div: ±5% (sample or average acquisition mode);
* vertical sensitivity is 5mV/div: ±4% (sample or average acquisition mode);
*When vertical sensitivity is 10mV/div~50V/div : ±3% (sample or average acquisition mode) - DC measurement accuracy (average acquisition mode):
*When vertical position is zero and N =16 :
± (5% x reading + 0.1 div + 1mV) and 1mV/div~2mV/div is selected;
± (4% x reading + 0.1 div + 1mV) and 5mV/div is selected;
± (3% x reading + 0.1 div + 1mV) and 10mV/div~50V/div is selected;
*When vertical position is not zero and N =16:
± [3% x (reading + vertical shift reading) + (1% x vertical shift reading)] + 0.2div). Set from 5mV/div to 200mV/div plus 2mV;
*Setup value > 200mV/div to 50V/div plus 50mV.
- Voltage difference (DV) : Under identical setup and
measurement accuracy : environmental conditions, the
(average acquisition mode) : voltage difference (DV) between any two points of the waveform after the : average of =16 waveforms acquired waveforms is taken : ± (3% x reading:+ 0.05 div)
Trigger Frequency Counter - Reading pixel aspect ratio : 6
- Trigger sensitivity : Internal trigger : £ 1 div; external trigger : £ 0.2V
- Trigger level range : ± 8 div from the centre of the screen
- Trigger level accuracy : ± (0.3 div x V/div) (within ± 4 div (Typical) applied on signals from the,centre of the screen) of ³20ns rise or fall time
- Pretrigger capability : Normal mode/scanning mode, pretrigger/delayed trigger. Pretrigger depth is adjustable
- Holdoff range : 100ns – 1.5s
- Set level to 50% (Typical) : Input signal frequency =50Hz
Edge Trigger - Edge type : Rise, fall, rise and fall
Pulse Trigger - Trigger mode : (Greater than, less than or equal to) positive pulse; (Greater than, less than or equal to) negative pulse
- Pulse width range : 20ns – 10s
Alternate Trigger - A Trigger : Edge, pulse
- B Trigger : Edge, pulse
Measurement - Cursor:
* :Manual mode :
:Voltage difference (DV) between cursors; time difference (DT) between :cursors; time difference (DT) countdown (Hz) (1/DT)
* ,Automatic : Cursor display is enabled measurement mode during , measurement - Automatic measurement : Peak-to-peak, amplitude, maximum, minimum, top, bottom, mean, average, root mean square, overshoot, preshoot, frequency, cycle, rising time, falling time, positive pulse,
negative pulse, positive duty ratio, negative duty ratio, delay. - Customized parameter : 3 types measurement
- Math functions : +, -, x, ÷
- Saving waveforms:
* Internal : 20 groups of waveforms and 20 setups
* USB : 200 groups of screens, 200 groups of waveforms - FFT:
* Window : Hanning,Hamming, Blackman- Harris, Rectangular
* Sampling points : 1024 points - Lissajous Figure:
* Phase difference : ± 3 degrees
- Display
- Display type : 178mm diagonal line (7”) LCD panel
- Display resolution : 800 horizontal x RGB x 480 vertical pixels (color)
- Display Colour : Color
- Waveform display zone : Lateral 12 div, 25 dot/div; Longitudinal 8 div, 25 dot/div
- Display contrast (Typical) : Adjustable
Backlight Intensity (Typical) : 300 nit
Display Languages : Simplified Chinese, Traditional Chinese, English, Spanish, Portuguese, French
- Interface Functions
Standard setup : 1 x USB OTG
- Power Source
Source Voltage : 100 – 240VACRMS, 45-440Hz, CAT II
Power Consumption : Less than 30VA
Fuse : F1.6AL 250V
- Environmental
Temperature Operating : 0°C~+40°C
Non-operating : -20 °C~+60°C
Cooling Method : Natural cooling
Humidity : +10°C~+30°C:= 95%±5% RH; +30°C~+40°C: = 75%±5% RH;
Altitude : Operating : under 3,000m Non-operating: under 15,000m
- Mechanical Specifications
Dimension (reference only) : 306mm x 147mm x 122mm (WxHxD)
Weight : Without packaging: 2.2kg With packaging: 3.3kg
IP Protection : IP2X
- Standard Accessories :
*Two 1.5m, 1:1 (10:1) passive voltage probes.
*One international standard power cord.
*One User Manual.
*Communication & control software.
*USB connection cable
Note: Specifications can be changed, added or subtracted without notice in our constant efforts for improvement.