Transmission Line Trainer (VPL-CT-TLT)
TECHNICAL SPECIFICATIONS
- Transmission Line : Coxial cable 100m (25m×4).
- Impedance Matching Resistances : 0-100W, 2 Nos.
- Test Generators : Sine wave 40KHz-400KHz (Low Range).
- Square wave 400KHz-4MHz.
- Test Points : More than 10.
- Interconnections : 2/4 mm socket.
- Cabinet : Enclosed in ABS plastic cabinet with detachable cover.
- Power : 220V AC ±10%, 50/60Hz mains operated
- Accessories : Mains cord, Set of patch cords Manual, BNCBNC Cable, BNC-Crocodile Cable.
LIST OF EXPERIMENTS
Measurement with Matched, Short & Open end of the line.
- Measurement of line properties.
- Measurement of line attenuation.
- Frequency characteristics of line.
- Input impedance of the line.
- Measurement of stationary waves.
- Phase shift along the line.
- Fault localization within the line.
- Line in pulsed condition.
OPTIONAL ACCESSORIES
- Multimedia interactive computer based training manual